used used blower, exhaust fan, grp-fan - 24235 - Typ: CMHR 42/GR90/C - Producer Ceilote Korrosionstechnik - TIPP Umwelt- und Verfahrenstechnik GmbH

used blower, exhaust fan, grp-fan




details to article: 24235

description: GRP - fan for conveying corrosive or aggressive gases. Due to the size the fan housing is dismantled at the moment.

Producer:Ceilote Korrosionstechnik
Typ:CMHR 42/GR90/C
Year of manufacture:1981
Pieces:1
Condition:gebraucht / used / second hand



technical data

price  2770 Euro EXW ()
  (shipping and payment)
Volume flow rate  65000 m³/h
Pressure  1570 Pa (pressure)
Temperature  60 °C (max. permissible temperature)
Rotations  590 1/min
Connections  1050 mm (cross section sucking side)
  1000 X 1000 mm (flange forcing side)
Dimensions 
Length  3200 mm
Width  2400 mm
Height  3100 mm
Weight  2500 kg (approx.)
Material  (housing made of GRP)
Material  (fan wheel made of coated steel)
Further information  (drive LOHER type A280MB-V8/4)
Power  75 kW (drive)


send request  
 
print view                       
 

Alle Angaben, Bilder, Hinweise und Empfehlungen erfolgen nach bestem
Wissen, je- doch ohne Gewähr. Änderungen der technischen Angaben bleiben vorbehalten.


Einige, ähnliche Artikel aus unserem derzeitigen Lagerbestand

Nr.:29951
gebrauchter Radial...
Nr.:29953
gebrauchter Radial...
Nr.:28489
gebrauchter Druckl...
Nr.:27561
gebrauchter Drehsc...
Nr.:29301
gebrauchtes Drehko...
Nr.:24667
gebrauchtes Wälzko...
Nr.:29683
gebrauchter Radial...
Nr.:24665
gebrauchtes Wälzko...
Nr.:29887
gebrauchter Verdic...

informations about: blowers / ventilators

A centrifugal fan ,also blower, or squirrel-cage fan, as it looks like a hamster wheel, is a mechanical device for moving air or other gases. It has a fan wheel composed of a number of fan blades, or ribs, mounted around a hub. The hub turns on a driveshaft that passes through the fan housing. The gas enters from the side of the fan wheel, turns 90 degrees and accelerates due to centrifugal force as it flows over the fan blades and exits the fan housing.
Centrifugal fans can generate pressure increases in the gas stream. Accordingly, they are well-suited for industrial processes and air pollution control systems. They are also common in central heating or cooling systems.
Centrifugal compressors, sometimes termed radial compressors, are a sub-class of dynamic axisymmetric work-absorbing turbomachinery.
Centrifugal impeller with a highly polished surface likely to improve performance
Jet engine cutaway showing the centrifugal compressor and other parts
The idealized compressive dynamic turbo-machine achieves a pressure rise by adding kinetic energy or velocity to a continuous flow of fluid through the rotor or impeller. This kinetic energy is then converted to an increase in potential energy or static pressure by slowing the flow through a diffuser.
Imagine a simple case where flow passes through a straight pipe to enter centrifugal compressor. The simple flow is straight, uniform and has no swirl. As the flow continues to pass into and through the centrifugal impeller, the impeller forces the flow to spin faster and faster. According to a form of Eulers fluid dynamics equation, known as pump and turbine equation, the energy input to the fluid is proportional to the flows local spinning velocity multiplied by the local impeller tangential velocity. In many cases the flow leaving centrifugal impeller is near or above 1000 ft. per s or approximately 300 m per s. It is at this point, in the simple case according to Bernoullis principle, where the flow passes into the stationary diffuser for the purpose of converting this velocity energy into pressure energy.
From Wikipedia, the free encyclopedia

email: mail@tipp-international.de
Internet: www.tipp-international.de

individual advice

We are characterized by experience and competence. Whether simple container units or large waste water treatment plants - put us to the test and we will gladly convince you of our services!

contact

You want to contact us? It's quite easy:

+49 5641 7447-0

We look forward to your questions and comments.

high-speed search

article search

simple article search or professional search. Our search engine is very easy to handle. Find here your used plant/component.
...article search

dismantling

Is does not matter - dismantling, decommission or relocation. We support you as fulfillment service supplier with specialist firms